Gas geyser installation

Electrical Installations installed this 20 liter gas geyser at Hendrik Potgieter str in Dalview Brakpan.
With a 48 litter gas bottle(cylinder) in a save area according to the safety rules. All pex pipes exposed to sun light was covered with PVC conduit to protect against UV rays from sun light. The gas pressure test to geyser using a KPA gauge can be seen on photos.

The existing electrical geyser remained as a backup, by teeing off the hot and cold water pipes to the gas geyser.
We use high standard special fittings, elbows valves etc. prescribed by LPGas regulations.
Special crimping tool must be used as seen on photos.

A notice sign for emergency shut off valve and information sign are also fitted next to valve and bottle.
The Gas Certificate of Compliance (COC) was issued to this property for this gas geyser installation.

For Gas geyser installations, contact Alwyn on 064 247 3812